Base and Din Rail Mounting Type-2

  • Base and Din Rail Mounting Type-2 - NDS-203P5DL1
Base and Din Rail Mounting Type-2
Model - NDS-203P5DL1
The switch is used to ensure that equipment or electrical system is completely de-energized for service or maintenance. Also, it can prevent the control panel (cabinet) be opened while it is on power.
It's certified by cULus, TUV, CE and its handle is lockable.
Besides, its switching speed is less than 0.3ms, so the consumption of contacts is very tiny and with great arc extinguishing performance.
There are auxiliary contact block and N pole can be chosen from.

Specification:
Pole: 3 Pole
Handel: P5 (65*65mm, Red/Yellow, Lockable, IP66)
Shaft Length: 150mm
Mounting Method: Din Rail/ Base Mounting
Rated insulation voltage, Ui: 690V
Thermal current Ith (AC1): 25A
AC3 Max. Horsepower rating/ Motor FLA current (3 Phase):
220~240V→ 3.7kW/ 5HP/ 15.2A
380~440V→ 7.5kW/ 10HP/ 14A
660~690V→7.5kW/ 10HP/ 11A
Enquiry Now
Products List
The switch is used to ensure that equipment or electrical system is completely de-energized for service or maintenance, so the control panel (cabinet) can’t be opened while it is on power. It's certified by CE, TUV, and cULus. The handle is lockable and with NEMA 4X approval. Also, the installation is very easy, just drill a 22mm hole on the panel and lock the fixing ring tightly. Besides, the switching speed is less than 0.3ms, so the consumption of contacts is very tiny and with great arc extinguishing performance. Except for the 150mm (Axle length), there are 200mm and 300mm can be chosen from, also there is black/ gray color option for the handle. Specification: Pole: 3 Pole Handel: G5 (67*67mm, Red/Yellow, Lockable, NEMA 4X) Shaft Length: 150mm Mounting Method: Din Rail/ Base Mounting Rated insulation voltage, Ui: 690V Thermal current Ith (AC1): 40A AC3 Max. Horsepower rating/ Motor FLA current (3 Phase): 220~240V→ 7.5kW/ 10HP/ 28A 380~440V→ 15kW/ 20HP/ 27A 660~690V→ 15kW/ 20HP/ 22A
This isolator is certified by CE and cULus. It is used to ensure that equipment or electrical system is completely de-energized for service or maintenance. It can prevent the control panel (cabinet) be opened while it is on power. The handle is with NEMA 4X (lockable), and it can be mounted in a 22mm hole by locking a fixing ring, very easy to install. Besides, its switching speed is less than 0.3ms, so the consumption of contacts is very tiny and with great arc extinguishing performance. The axle length is adjustable. There is 10 to 15 mm range available; also customers can cut the axle directly to fit the depth of the control cabinet/ panel. Specification: Pole: 3 Pole Handel: G5 (67*67mm, Red/Yellow, Lockable, NEMA 4X) Shaft Length: 150mm Mounting Method: Din Rail/ Base Mounting Rated insulation voltage, Ui: 690V Thermal current Ith (AC1): 100A AC3 Max. Horsepower rating/ Motor FLA current (3 Phase): 220~240V→ 18.5kW/ 25HP/ 68A 380~440V→ 30kW/ 40HP/ 52A 660~690V→ 30kW/ 40HP/ 41A
This isolator is CE and cULus certified. It is used to ensure that equipment or electrical system is completely de-energized for service or maintenance and available to prevent to open the control panel (cabinet) while there is on power. It is widely used in all kinds of low voltage switchgear, motor control center and also power control box, etc. The handle is lockable and with NEMA 4X. The installation is very easy, just drill a 22mm hole on the panel and lock the fixing ring tightly. Besides, its switching speed is less than 0.3ms, so the consumption of contacts is very tiny and with great arc extinguishing performance. Specification: Pole: 3 Pole Handel: G4 (48*48mm, Black/Gray, Lockable, NEMA 4X) Shaft Length: 150mm Mounting Method: Din Rail/ Base Mounting Rated insulation voltage, Ui: 690V Thermal current Ith (AC1): 100A AC3 Max. Horsepower rating/ Motor FLA current (3 Phase): 220~240V→ 18.5kW/ 25HP/ 68A 380~440V→ 30kW/ 40HP/ 52A 660~690V→ 30kW/ 40HP/ 41A
The switch is used to ensure that equipment or electrical system is completely de-energized for service or maintenance. The switch part is certified by CE, TUV, and cULus. Its switching speed is less than 0.3ms, so the consumption of contacts is very tiny and with great arc extinguishing performance.   If customers have other demands on the color, there are Red/ Yellow color handle and Yellow/ Black color enclosure available. Plastic screws with fool-proof design, so it won’t get rust and won't come off when lose. It can equip with the cable gland of PG16 (M20) to reach IP 66 rating. The structure of inside is with din rail design, so the switch can be assembled directly. Enclosure’s dimension is 130mm x 105mm x 95mm (L*W*H).   Specification: Pole: 3 Pole Handel: G5 (67*67mm, Black/ Gray, Lockable, NEMA 4X) Enclosure: IP66 rating, Gray Lid/ Black Base Rated insulation voltage, Ui: 690V Thermal current Ith (AC1): 40A AC3 Max. Horsepower rating/ Motor FLA current (3 Phase): 220~240V→ 7.5kW/ 10HP/ 28A 380~440V→ 15kW/ 20HP/ 27A 660~690V→ 15kW/ 20HP/ 22A