AC Contactor-1
AC Contactor-1
Model - C-09D
It is a 3 pole AC contactor with completed international approvals: cCSAus, CE, UL, CCC, CNS.
The coil can be connected from the opposite side and also the same side, makes the using be more flexible.
The specification is as below:
Contacts: 3NO+1a or 3NO+1b
Rated insulation voltage, Ui: 1000V
Thermal current Ith (AC1): 20A
Rated Operational Current (AC3): 9A
Mechanical Durability: 5 Mil. Cycles (1200 cycles/hr.)
Electrical Durability: 0.5 Mil. Cycles (1200 cycles/hr.)
Rated Capacity for 3Phase AC3 (kW/A):
220V→ 2.2kW/3HP
380V→ 3.7kW/5HP
575V→ 3.7kW/5HP
Auxiliary Contacts: CA1 (Top mounting) & CA8 (Side mounting)
Overload Relay: NTH series
Electric & Mechanical Interlock: CA9 (Two functions in one)
The coil can be connected from the opposite side and also the same side, makes the using be more flexible.
The specification is as below:
Contacts: 3NO+1a or 3NO+1b
Rated insulation voltage, Ui: 1000V
Thermal current Ith (AC1): 20A
Rated Operational Current (AC3): 9A
Mechanical Durability: 5 Mil. Cycles (1200 cycles/hr.)
Electrical Durability: 0.5 Mil. Cycles (1200 cycles/hr.)
Rated Capacity for 3Phase AC3 (kW/A):
220V→ 2.2kW/3HP
380V→ 3.7kW/5HP
575V→ 3.7kW/5HP
Auxiliary Contacts: CA1 (Top mounting) & CA8 (Side mounting)
Overload Relay: NTH series
Electric & Mechanical Interlock: CA9 (Two functions in one)
Enquiry Now
Products List
It is a 3 pole AC contactor with completed international approvals: cCSAus, CE, UL, CCC, CNS.
NHD was established in 1979, with over 40 years of experience, starting from custom low voltage control panel and producing contactor. Therefore, we are skilled in technology and have rich professional knowledge. Welcome to contact us if you have any questions or special demands.
The specification is as below:
Contacts: 3NO+1a or 3NO+1b
Rated insulation voltage, Ui: 1000V
Thermal current Ith (AC1): 40A
Rated Operational Current (AC3): 32A
Mechanical Durability: 5 Mil. Cycles (1200 cycles/hr.)
Electrical Durability: 0.5 Mil. Cycles (1200 cycles/hr.)
Rated Capacity for 3Phase AC3 (kW/A):
220V→ 7.5kW/10HP
380V→ 15kW/20HP
575V→ 15kW/20HP
Auxiliary Contacts: CA1 (Top mounting) & CA8 (Side mounting)
Overload Relay: NTH series
Electric & Mechanical Interlock: CA9 (Two functions in one)
It is a 3 pole AC contactor with CE, and CCC approvals.
All products are made in Taiwan, so we are available to make the voltage and frequency according to customer’s demand.
If there is any special requirement, welcome to discuss with us.
The specification is as below:
Contacts: 3NO,1NO+1NC
Rated insulation voltage, Ui: 1000V
Thermal current Ith (AC1): 60A
Rated Operational Current (AC3): 55A
Mechanical Durability: 5 Mil. Cycles (1200 cycles/hr.)
Electrical Durability: 0.5 Mil. Cycles (1200 cycles/hr.)
Rated Capacity for 3Phase AC3 (kW/A):
220V→ 15kW/20HP
380V→ 30kW/40HP
575V→ 30kW/40HP
Auxiliary Contacts: CA1 (Top mounting) & CA8 (Side mounting)
Overload Relay: NTH series
Electric & Mechanical Interlock: CA9 (Two functions in one)
It is a 3 pole AC contactor with CE, and CCC approvals.
This is the maximum one of the C series, whose thermal current (AC1) is 130A and it is 40HP at AC 220V.
If there is a demand for higher capacity, please refer to the S-C series, above S-C100 type.
The specification is as below:
Contacts: 3NO,1NO+1NC
Rated insulation voltage, Ui: 1000V
Thermal current Ith (AC1): 130A
Rated Operational Current (AC3): 110A
Mechanical Durability: 5 Mil. Cycles (1200 cycles/hr.)
Electrical Durability: 0.5 Mil. Cycles (1200 cycles/hr.)
Rated Capacity for 3Phase AC3 (kW/A):
220V→ 30kW/40HP
380V→ 55kW/75HP
575V→ 60kW/80HP
Auxiliary Contacts: CA1 (Top mounting) & CA8 (Side mounting)
Overload Relay: NTH series
Electric & Mechanical Interlock: CA9 (Two functions in one)
It is a 3 pole AC contactor with CE approval.
The quality is great enough to be sold into the Korean market.
The specification is as below:
Contacts: 3NO, 1NO+1NC
Rated insulation voltage, Ui: 1000V
Thermal current Ith (AC1): 20A
Rated Operational Current (AC3): 9A
Mechanical Durability: 5 Mil. Cycles (1200 cycles/hr.)
Electrical Durability: 0.5 Mil. Cycles (1200 cycles/hr.)
Rated Capacity for 3Phase AC3 (kW/A):
220V→ 2.2kW/3HP
380V→ 3.7kW/5HP
440V→ 3.7kW/5HP
Auxiliary Contacts: SMC-D11 (Side mounting), CA2 & CA4 (Top mounting).
Overload Relay: NTH series
It is a 3 pole AC contactor with CE approval.
The standard type is equipped with 2a2b auxiliary contact block, but since the auxiliary contact block is detachable, it can follow customers' demand to do the combination.
The specification is as below:
Contacts: 3NO, 2NO+2NC
Rated insulation voltage, Ui: 1000V
Thermal current Ith (AC1): 60A
Rated Operational Current (AC3): 42A
Mechanical Durability: 5 Mil. Cycles (1200 cycles/hr.)
Electrical Durability: 0.5 Mil. Cycles (1200 cycles/hr.)
Rated Capacity for 3Phase AC3 (kW/A):
220V→ 11kW/15HP
380V→ 19kW/25HP
440V→ 19kW/25HP
Auxiliary Contacts: SMC-D11 (Side mounting), CA2 & CA4 (Top mounting).
Overload Relay: NTH series
It is a 3 pole AC contactor with CE approval.
The auxiliary contact block of this model is detachable.
Customers can change it according to demands, making the price be more competitive and using be more flexible.
The specification is as below:
Contacts: 3NO, 2NO+2NC
Rated insulation voltage, Ui: 1000V
Thermal current Ith (AC1): 100A
Rated Operational Current (AC3): 65A
Mechanical Durability: 5 Mil. Cycles (1200 cycles/hr.)
Electrical Durability: 0.5 Mil. Cycles (1200 cycles/hr.)
Rated Capacity for 3Phase AC3 (kW/A):
220V→ 19kW/25HP
380V→ 33kW/45HP
440V→ 33kW/45HP
Auxiliary Contacts: SMC-D11 (Side mounting), CA2 & CA4 (Top mounting).
Overload Relay: NTH series
It is a 3 pole AC contactor with CE approval and it’s the maximum contactor of the SMC series.
The standard type is equipped with 2a2b auxiliary contact block, which is detachable. We can follow customer’s demand to manufacture it, also diverse clients’ use.
The specification is as below (AC):
Contacts: 3NO, 2NO+2NC
Rated insulation voltage, Ui: 1000V
Thermal current Ith (AC1): 160A
Rated Operational Current (AC3): 110A
Mechanical Durability: 5 Mil. Cycles (1200 cycles/hr.)
Electrical Durability: 0.5 Mil. Cycles (1200 cycles/hr.)
Rated Capacity for 3Phase AC3 (kW/A):
220V→ 30kW/40HP
380V→ 55kW/75HP
440V→ 55kW/75HP
Auxiliary Contacts: SMC-T11 (Side mounting), CA2 & CA4 (Top mounting).
Overload Relay: NTH series